Homesessive Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. ICD-10 - Wikipedia

    en.wikipedia.org/wiki/ICD-10

    ICD-10 is the 10th revision of the International Classification of Diseases (ICD), a medical classification list by the World Health Organization (WHO). It contains codes for diseases, signs and symptoms, abnormal findings, complaints, social circumstances, and external causes of injury or diseases. [1]

  3. CIE 1931 color space - Wikipedia

    en.wikipedia.org/wiki/CIE_1931_color_space

    Thus the CIE 1931 Standard Observer function is also known as the CIE 1931 2° Standard Observer. A more modern but less-used alternative is the CIE 1964 10° Standard Observer, which is derived from the work of Stiles and Burch, [9] and Speranskaya. [10] For the 10° experiments, the observers were instructed to ignore the central 2° spot.

  4. Template:Color temperature white points - Wikipedia

    en.wikipedia.org/wiki/Template:Color_temperature...

    A list of standardized illuminants, their CIE chromaticity coordinates (x,y) of a perfectly reflecting (or transmitting) diffuser, and their correlated color temperatures (CCTs) are given below. The CIE chromaticity coordinates are given for both the 2 degree field of view (1931) and the 10 degree field of view (1964). [1]

  5. Standard illuminant - Wikipedia

    en.wikipedia.org/wiki/Standard_illuminant

    The CIE positions D65 as the standard daylight illuminant: [D65] is intended to represent average daylight and has a correlated colour temperature of approximately 6500 K. CIE standard illuminant D65 should be used in all colorimetric calculations requiring representative daylight, unless there are specific reasons for using a different illuminant.

  6. Color rendering index - Wikipedia

    en.wikipedia.org/wiki/Color_rendering_index

    [9] [10] CRI is based upon this system of colorimetry. [11] To deal with the problem of having to compare light sources of different correlated color temperatures (CCT), the CIE settled on using a reference black body with the same color temperature for lamps with a CCT of under 5000 K, or a phase of CIE standard illuminant D (daylight ...

  7. Luminous efficiency function - Wikipedia

    en.wikipedia.org/wiki/Luminous_efficiency_function

    The CIE photopic luminous efficiency function y (λ) or V(λ) is a standard function established by the Commission Internationale de l'Éclairage (CIE) and standardized in collaboration with the ISO, [1] and may be used to convert radiant energy into luminous (i.e., visible) energy.

  8. Whiteness (colorimetry) - Wikipedia

    en.wikipedia.org/wiki/Whiteness_(colorimetry)

    To promote uniformity of practice in the evaluation of whiteness of surface colors, it is recommended that the formulæ for whiteness, W 2 or W 10, and for tint, T w,2 or T w,10, given below, be used for comparisons of the whiteness of samples evaluated for CIE standard illuminant D65. The application of the formulae is restricted to samples ...

  9. International Classification of Diseases - Wikipedia

    en.wikipedia.org/wiki/International...

    ICD-10-CA is a clinical modification of ICD-10 developed by the Canadian Institute for Health Information for morbidity classification in Canada. ICD-10-CA applies beyond acute hospital care, and includes conditions and situations that are not diseases but represent risk factors to health, such as occupational and environmental factors ...